AOI Handlings system

The AOI handling system is a compact facility with various test units. Via an ionization cleaning station the ceramics are transferred to the contacting station. There, the resistance values of the substrates are tested with a rigid needle adapter. Afterward, the ceramics are further conveyed to the three (optionally four) AOI test stations (for automatic optical inspection) and are tested for cracks, unevenness, faulty imprints, contamination, etc. The poorly evaluated ceramics arrive at a review station where the operator can assess and evaluate the errors on the monitor. If the operator is uncertain about a fault, the ceramic in question can be positioned under the microscope position and inspected by eye. Poorly defined ceramics are marked accordingly with an ink pen.

Further informationen
EPP – www.epp-germany.com
Stratus Vision - www.stratusvision.com

Kontaktierstation
Cleaning and contacting

Markierstation
Marker station and Checker

Your contact person
Adrian Bangerter
+41 62 285 80 13
This email address is being protected from spambots. You need JavaScript enabled to view it.

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.